Sale
°C


Product description
- Passive
- -5...+60 °C
- 2-wire connection
Resistance thermometer THERMASGARD® RPTF 1 with passive output, specially designed for temperature detection in larger rooms or halls.
Due to the measuring method used for room pendulum sensors and the positioning in the room, a very good measurement result representative of the measuring room is achieved, as the sensor is evenly circulated by the surrounding room air.resistance thermometer THERMASGARD® RPTF 2 with passive output, which is specially designed for temperature detection in larger rooms or halls, e.g. as a dark radiation sensor. The RPTF 2 room pendulum sensor (globethermometer) determines the effective radiant component or the effective radiant heat at the measurement location. Due to the measuring method used for room pendulum sensors and the positioning in the room, a very good measuring result is achieved that is representative of the measuring room. The globe temperature is determined to take account of the radiant heat and calculate the thermal comfort (operative room temperature). The operative room temperature describes the interaction of heat radiation and heat convection (the globe temperature is approx. 70% to 30% of the air temperature).
Due to the measuring method used for room pendulum sensors and the positioning in the room, a very good measurement result representative of the measuring room is achieved, as the sensor is evenly circulated by the surrounding room air.resistance thermometer THERMASGARD® RPTF 2 with passive output, which is specially designed for temperature detection in larger rooms or halls, e.g. as a dark radiation sensor. The RPTF 2 room pendulum sensor (globethermometer) determines the effective radiant component or the effective radiant heat at the measurement location. Due to the measuring method used for room pendulum sensors and the positioning in the room, a very good measuring result is achieved that is representative of the measuring room. The globe temperature is determined to take account of the radiant heat and calculate the thermal comfort (operative room temperature). The operative room temperature describes the interaction of heat radiation and heat convection (the globe temperature is approx. 70% to 30% of the air temperature).
We also manufacture individually
Do you have special requirements?As a manufacturer with our own production facilities in Germany, we are always in a position to produce products outside the standard range.
Contact us
Secure payment methods
Do you have a question? We are at your disposal:
+49 911 519 470
Mo. - Fr. 7:00 - 17:00 Uhr